A. Krupa, J. Gangloff, C Doignon, M. de Mathelin, G. Morel, J. Leroy, L. Soler, J. Marescaux. Autonomous 3-D positioning of surgical instruments in robotized laparoscopic surgery using visual servoing. IEEE Trans. on Robotics and Automation, Special issue on Medical Robotics, R.H. Taylor (eds.), 19(5):842-853, October 2003.

Download [help]

Download paper: Doi page

Download paper: Adobe portable document (pdf) pdf

Copyright notice:

This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each author's copyright. These works may not be reposted without the explicit permission of the copyright holder. This page is automatically generated by bib2html v217, © Inria 2002-2015, Projet Lagadic

Abstract

This paper presents a robotic vision system that automatically retrieves and positions surgical instruments during robotized laparoscopic surgical operations. The instrument is mounted on the end-effector of a surgical robot which is controlled by visual servoing. The goal of the automated task is to safely bring the instrument at a desired three-dimensional location from an unknown or hidden position. Light-emitting diodes are attached on the tip of the instrument, and a specific instrument holder fitted with optical fibers is used to project laser dots on the surface of the organs. These optical markers are detected in the endoscopic image and allow localizing the instrument with respect to the scene. The instrument is recovered and centered in the image plane by means of a visual servoing algorithm using feature errors in the image. With this system, the surgeon can specify a desired relative position between the instrument and the pointed organ. The relationship between the velocity screw of the surgical instrument and the velocity of the markers in the image is estimated online and, for safety reasons, a multistages servoing scheme is proposed. Our approach has been successfully validated in a real surgical environment by performing experiments on living tissues in the surgical training room of the Institut de Recherche sur les Cancers de l'Appareil Digestif (IRCAD), Strasbourg, France

Contact

Alexandre Krupa

BibTex Reference

@article{krupa03d,
   Author = {Krupa, A. and Gangloff, J. and Doignon, C and de Mathelin, M. and Morel, G. and Leroy, J. and Soler, L. and Marescaux, J.},
   Title = {Autonomous 3-D positioning of surgical instruments in robotized laparoscopic surgery using visual servoing},
   Journal = {IEEE Trans. on Robotics and Automation},
   Volume = {19},
   Number = {5},
   Pages = {842--853},
   Month = {October},
   Year = {2003}
}

EndNote Reference [help]

Get EndNote Reference (.ref)

| Lagadic | Map | Team | Publications | Demonstrations |
Irisa - Inria - Copyright 2009 © Lagadic Project